Over time, it is advisable to check their condition regularly. If you find that the brush and silicone cloths have been lowered, this article will show you how to readjust them.
Tools | |
Allen key 2.5mm |
1. Uninstall the purge bucket
Lift the purge bucket until the tabs are released and remove the purge bucket from its position.
2. Remove the printed part
There are two screws in the front corner of the purge bucket that must be removed to detach the part that holds the purge bucket brush and silicone cloths.
3. Adjusting the Purge Bucket Brush and Silicone Cloths
The printed part has a screw that levels the brush. Use an Allen wrench and screw or unscrew it to raise or lower it.
Do this procedure until you find the point where the hotend tip comes through the brush.
To adjust the silicone cloths, loosen the screws that hold them in place and adjust them manually. Once in position, re-tighten the screws.
Reinstall the purge bucket with the adjustments you have made as many times as necessary until you find the correct position.
4. Reinstall the purge bucket
Place the printed piece in the corner of the purge bucket and tighten the two screws holding the piece in place. Reinstall the purge bucket, aligning the pins with the mounting holes and slide the purge bucket until it is properly seated.
Make sure that the hotend tip does not collide with the purge bucket, but rubs against the brush and silicone cloths.
Remember that the purge buckets are facing each other, so the parts must go with their corresponding purge bucket.