1. Loosen the two screws that hold the endstop to the aluminum holder. screw-icon x2 M3 12mm

x endstop screws

 

2. Disconnect the endstop by pulling from the cable connections. The next image shows you the terminals and how you should connect it. In case you also need to replace the cable, continue with step 3.

endstop-connection-3

endstop-connection-4

Note: Before step 3, remove the protective cover on the side you want the change the x endstop.

3. Cut the two tie wraps that hold the endstop cable.

x endstop tie wraps

 

4. Disconnect the endstop from the driver.

x driver endstop connection

 

5. Install the new endstop as shown in the picture, the cable has to go under the X guide and the orange switch has to be at the bottom part of the endstop.

x endstop cable

 

Conclusions

Make sure that the endstop cable is immobilized with tie wrappers to avoid it being caught on moving parts of the printer.

Forum community 

Repair didn’t go as planned? Check out our forum community for troubleshooting help.

 

It's important to keep your printer in good shape to make the most out of it. In this chart, you can find a list of the extruder maintenance procedures and how frequently these should be done. Maintenance Plan

 

bcn3d-recycle  Take your e-waste to a certified recycler. Check how we do it in BCN3D.

 

Parts   Buy these parts
x-endstop-component Endstop X

SKU 16158

 


RELATED ARTICLES

check flat cable eng check mainboard fuse eng

 

You can help improve the BCN3D Knowledge Base. 

If you feel there are guides that we are missing or you found any error, please use this form to report it. Report form :)