How to replace the Y endstop (BCN3D Sigma)

 

Tools  
socket-driver-icon
5mm socket driver


This guide shows you how to change the Y endstop. To do so, follow these steps:

 

1. Turn off and disconnect your BCN3D Sigma from the power source.

sigma-turn-off-1 sigma-turn-off-2

 

2. Take out the bowden tube by pressing down on the coupling collet and pulling the bowden out. This will give you a better access to the Endstop. 

take-out-bowden

 

3. Unscrew the nuts that hold the endstop in place with a 5mm socket driver.  nut-iconx2 M3


unscrew-endstop

 

4. Take out the Endstop, you'll need to wiggle it a bit in order to take it out:

take-out-endstop

5. Disconnect the endstop from the Y driver and extract it from the printer. Note that the Endstop cable passes behind the Y transmission bar. 

disconect-endstop

 

6. To install the new endstop, follow the same steps in reverse order. 

 